Posts

SonicWall Firmware Maintenance Release 5.9.2.x for NSA TZ Seial

Platform Compatibility • NSA E8510 • NSA E8500 • NSA E7500 • NSA E6500 • NSA E5500 • NSA 5000 • NSA 4500 • NSA 3500 • NSA 2400 • NSA 2400MX • NSA 250M / NSA 250M Wireless • NSA 240 • NSA 220 / NSA 220 Wireless • TZ 215 / TZ 215 Wireless • TZ 210 / TZ 210 Wireless • TZ 205 / TZ 205 Wireless • TZ 200 / TZ 200 Wireless • TZ 105 / TZ 105 Wireless • TZ 100 / TZ 100 Wireless Use at your own risk 5.9.2.13 http://software.sonicwall.com/Firmware/sw_nsa-e8510__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e8500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e7500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e6500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e5500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-5000__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-4500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-3500__eng_5.9.2.13-7o.sig http://software....

Adtran Serial console

Adtran Serial Console setting Baud rate: 9600 Data bit: 8 Parity: none Stop: 1 Flow control: 1

Unifi UAP-LR

 UAP-LR Firmware upgrade path upgrade http://dl.ui.com/unifi/firmware/BZ2/3.2.12.2920/BZ.ar7240.v3.2.12.2920.150531.1645.bin upgrade http://dl.ui.com/unifi/firmware/BZ2/3.7.58.6385/BZ.ar7240.v3.7.58.6385.170508.0942.bin

How to Performing Logic Reset on APC Smart-UPS and a cold start and brain dead on Smart-UPS

 https://www.apc.com/us/en/faqs/FA156611/ https://youtu.be/Q4-0lAVBATM https://youtu.be/jeVqtc2dbbc Cause: The Cold start procedure is used to determine if a UPS is functional if it will not turn on when plugged into utility power. The Brain Dead procedure performs a hard reset of the Smart-Ups microprocessor. It does not however reset saved preferences. Resolution: Cold Start: This is a great way to establish if a UPS will not turn on due to bad input power. Never use a Cold Start to troubleshoot a bad battery LED as it will clear the light most every time even if the battery is actually bad. This is because the self-test is comparing the battery health compared to the load attached. If there is no load attached, the battery will appear healthy.   1) Turn off and unplug the Smart-UPS from wall. Remove any attached load. 2) Press and hold the power button (labeled ""I/TEST"" on legacy non-LCD screen units) on the front of the UPS until you hear a LONG beep. 3) Let g...

Fax with Obi + Google Voice

Image
 http://www.obitalk.com/forum/index.php?topic=17418.0 I have seen here that many people say that GV and Obi work "out of the box" for faxing, however in my tests I was unable to reliably connect at any speed higher than 14.4kbps with Obi "out of the box". I looked around and found the five settings in the Physical Interfaces > Phone 2 settings (see attached) 1 Disable call waiting (Checked) 2 Use for Fax Only (checked if using dedicated fax only) 3 Fax Detection Medthod (CNG or CED) 4 Detect Phone CED Phase Reversal (Checked) 5 Detect Network CED Phase reversal (Checked) With the above settings on my GV dedicated Fax line on port 2 of Obi202 I have managed to fax at 33.6kbps far more reliably. Updating this post to show the additional Fax settings that I've  found for my dedicated Fax line (See Attached) CallWaitingEnable (unchecked) UseForFaxOnly (Checked) DetectFaxPageBreak (Checked) UseForModemOnly (Unchecked) FaxDetectionMethod (CNG or CED) DetectPhoneCED...

APC UPS Discharge problem reset / fix

APC UPS Discharge problem reset/fix (instructions) http://www.joeteck.com/apc.htm "Remove the net card" Serial Setting  2400 Baud 8 bits 1 stop no parity Xon/Xof This is for the following people who have these symptoms •  You ran Power chute software and noticed your run time is less than it should be. •  You replaced your batteries with a new one(s) and your run time is still very low. •  Your Battery LED lights are flashing/blinking without a full load. •  Your UPS program tells you, "UPS battery is discharged" from power chute software. Follow these steps to repair this un-documented solution. ***You need the smart-UPS serial cable to do this process. It is black, not gray. ***     •  Close power chute software, and stop the "APC - UPS power chute" service. •  Open HyperTerminal. Start > Programs > Accessories > Hyperterminal > Hyperterminal •  Enter in a name, such as APC repair. •  Be sure the settings are as follow...

Adtran CLI

 show ip interface Debug Output COMMAND DESCRIPTION show debugging shows current enabled debug commands debug sip stack messages shows sip debug information debug isdn l2-formatted shows isdn debug information (easier use) debug voice verbose shows all voice messaging debug isdn verbose shows all isdn messaging debug interface T1 0/4 rbs shows robbed bit signaling from CAS circuit undebug all turns off all debugging Utility Commands COMMAND DESCRIPTION clear count media counters on media-gateway reset clear counters clears counters on interfaces no events turns off messages to the current session ping ping an IP address traceroute trace the router path to a destination IP address wall sends a broadcast message to all current users sip trunk-registration force-register forces sip re-registration Show Commands COMMAND DESCRIPTION show sip trunk-registration shows registration status show media-gateway summary shows media gateway channel status show media-gateway channel 0/2.1 shows m...

How to add additional IP (Secondary IP) in Ubuntu system

  # vi /etc/network/interfaces # interfaces(5) file used by ifup(8) and ifdown(8) auto lo iface lo inet loopback # The primary network interface auto enp0s3 iface enp0s3 inet static address 192.168.56.201 netmask 255.255.255.0 iface enp0s3 inet static address 192.168.56.202 netmask 255.255.255.0 gateway 192.168.56.1 network 192.168.56.0 broadcast 192.168.56.255 dns-nameservers 8.8.8.8 8.8.4.4 dns-search 2daygeek.local

How to Enable / Disable Multiple RDP Sessions in Windows 2012

Image
  How to Enable / Disable Multiple RDP Sessions in Windows 2012 Plesk Servers  >  Dedicated Server     How to Enable/Disable Multiple RDP Sessions in Windows 2012 By default, Windows 2012 servers allow a single Remote Desktop session. If only one session is available and you take over another person's live session, you may choose to enable multiple RDP sessions. This article describes the process for enabling and disabling multiple sessions. Enable Multiple RDP Sessions Log into the server using  Remote Desktop . Open the start screen (press the Windows key) and type  gpedit.msc  and open it Go to  Computer Configuration > Administrative Templates > Windows Components > Remote Desktop Services > Remote Desktop Session Host > Connections . Set  Restrict Remote Desktop Services user to a single Remote Desktop Services session  to  Disabled. Double click  Limit number of connections  and set the RD Maxi...

TsPlus problem max 2 users

  1 - Please update your TSplus to the latest version, reboot the server and try again. You can get the update here : [ dl-files.com ] Make sure no users are logged in before installing this update, you can check for remote users by launching a task manager and clicking on the Users tab. Disabling your antivirus is also recommended. Make a scan exclusion rule on C:\wsession and C:\Program Files (x86)\TSplus\UserDesktop\files and make sure your users have sufficient rights to read and execute all programs in these folders. 2 - If it still doesn't work, then it means that a Windows update has impacted the RDP connection module and has overwritten the TSplus settings. - open a DOS command prompt as administrator - navigate to the tsplus \ userdesktop \ files installation directory - run 'svcac.exe /updatekernel' - after the popup, - open the Windows Services Manager - restart the Application Publishing Service After that, you should return to normal operation in multi-session ...

QuikBooks update

 https://www.qtools.com/qbupdates.htm U.S. Editions Only Version Name Internal Version Number SDK Versions Update Page Edition Direct Download (from Intuit server) 2020 Ent 20.0 30.0 1.0 - 13.0 Link 3 PRO & PREMIER R3 ,  R4 ,  R5 ,  R6 ,  R7 ENTERPRISE R3 ,  R4 ,  R5 ,  R6 ,  R7 2019 Ent 19.0 29.0 1.0 - 13.0 Link 3 PRO & PREMIER R3 ,  R4 ,  R5 ,  R6 ,  R7 ,  R8 ,  R9 ,  R10 ,  R11 ,  R12 ENTERPRISE R3 ,  R4 ,  R5 ,  R6 ,  R7 ,  R8 ,  R9 ,  R10 ,  R11 ,  R12 2018 Ent 18.0 28.0 1.0 - 13.0 Link 3 PRO & PREMIER R3 ,  R4 ,  R5 ,  R6 ,  R7 ,  R8 ,  R9 ,  R10 ,  R11 ,  R12 ,  R13 ,  R14 ,  R15 ENTERPRISE R3 ,  R4 ,  R5 ,  R6 ,  R7 ,  R8 ,  R9 ,  R10 ,  R11 ,  R12 ,  R13 ,  R14 ,  R15 2017 Ent 17.0 27.0 1.0 - 13.0 Link 3 PRO & P...

Cannot access the Offline Files tab

 If you cannot access the Offline Files tab, use this method to re-initialize the Offline Files (CSC) cache on the system by modifying the registry. Use this method also to re-initialize the offline files database/client-side cache on multiple systems. Add the following registry subkey:  HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\NetCache  Key Name: FormatDatabase  Key Type: DWORD  Key Value: 1 Note The actual value of the registry key is ignored. This registry change requires a restart. When the computer is restarting, the shell will re-initialize the CSC cache, and then delete the registry key if the registry entry exists.  Warning All cache files are deleted and unsynchronized data is lost. 

Powershell Scripting : Windows Firewall Block by Country

 Powershell Scripting : Windows Firewall Block by Country https://www.itlumberjack.com/microsoft/21-windows-firewall-block-by-country This script is designed to place an extra layer of security on Windows machines. Servers running IIS, Apache, or Nginx are extremely vulnerable since they require ports 80 and 443 to be open to the internet. The script pulls a list of IP addresses from  www.ipdeny.com  . IP Deny provides a list of IP ranges for each country.  The script can be run as a task. This will help in making sure that the IP addresses being blocked are current. Before scheduling a task please be sure to review IP Deny's usage policy.  https://www.ipdeny.com/usagelimits.php Please note that this should not be your first line of defense in blocking unwanted inbound traffic. Best practice would be to block the traffic on an edge device such as a hardware firewall. In the event, the attacker is able to get past the hardware firewall, this would serve as a...

Setting the PowerShell Execution Policy

Image
  Solution There are situations when you are executing a PowerShell script and it will give you the below error message: File C:\scripts\regSvr.ps1 cannot be loaded because the execution of scripts is disabled on this system. Please see "get- help about_signing" for more details. At line:1 char:19 + c:\scripts\regSvr.ps1 <<<< The reason for the above error is a security setting built into Windows PowerShell called  "execution policy".  Execution Policy determines how (or if) PowerShell runs scripts. By default, PowerShell's  execution policy  is set to  Restricted ; this means that scripts will not run. You can verify the execution policy setting by using the  Get-ExecutionPolicy  PowerShell command as shown below. get-executionpolicy You can change the PowerShell script execution behavior using  "Set-ExecutionPolicy" . The  Set-ExecutionPolicy  cmdlet enables you to determine which Windows PowerShell scripts will be all...