Posts

Showing posts from October, 2020

SonicWall Firmware Maintenance Release 5.9.2.x for NSA TZ Seial

Platform Compatibility • NSA E8510 • NSA E8500 • NSA E7500 • NSA E6500 • NSA E5500 • NSA 5000 • NSA 4500 • NSA 3500 • NSA 2400 • NSA 2400MX • NSA 250M / NSA 250M Wireless • NSA 240 • NSA 220 / NSA 220 Wireless • TZ 215 / TZ 215 Wireless • TZ 210 / TZ 210 Wireless • TZ 205 / TZ 205 Wireless • TZ 200 / TZ 200 Wireless • TZ 105 / TZ 105 Wireless • TZ 100 / TZ 100 Wireless Use at your own risk 5.9.2.13 http://software.sonicwall.com/Firmware/sw_nsa-e8510__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e8500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e7500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e6500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-e5500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-5000__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-4500__eng_5.9.2.13-7o.sig http://software.sonicwall.com/Firmware/sw_nsa-3500__eng_5.9.2.13-7o.sig http://software....

Adtran Serial console

Adtran Serial Console setting Baud rate: 9600 Data bit: 8 Parity: none Stop: 1 Flow control: 1

Unifi UAP-LR

 UAP-LR Firmware upgrade path upgrade http://dl.ui.com/unifi/firmware/BZ2/3.2.12.2920/BZ.ar7240.v3.2.12.2920.150531.1645.bin upgrade http://dl.ui.com/unifi/firmware/BZ2/3.7.58.6385/BZ.ar7240.v3.7.58.6385.170508.0942.bin

How to Performing Logic Reset on APC Smart-UPS and a cold start and brain dead on Smart-UPS

 https://www.apc.com/us/en/faqs/FA156611/ https://youtu.be/Q4-0lAVBATM https://youtu.be/jeVqtc2dbbc Cause: The Cold start procedure is used to determine if a UPS is functional if it will not turn on when plugged into utility power. The Brain Dead procedure performs a hard reset of the Smart-Ups microprocessor. It does not however reset saved preferences. Resolution: Cold Start: This is a great way to establish if a UPS will not turn on due to bad input power. Never use a Cold Start to troubleshoot a bad battery LED as it will clear the light most every time even if the battery is actually bad. This is because the self-test is comparing the battery health compared to the load attached. If there is no load attached, the battery will appear healthy.   1) Turn off and unplug the Smart-UPS from wall. Remove any attached load. 2) Press and hold the power button (labeled ""I/TEST"" on legacy non-LCD screen units) on the front of the UPS until you hear a LONG beep. 3) Let g...

Fax with Obi + Google Voice

Image
 http://www.obitalk.com/forum/index.php?topic=17418.0 I have seen here that many people say that GV and Obi work "out of the box" for faxing, however in my tests I was unable to reliably connect at any speed higher than 14.4kbps with Obi "out of the box". I looked around and found the five settings in the Physical Interfaces > Phone 2 settings (see attached) 1 Disable call waiting (Checked) 2 Use for Fax Only (checked if using dedicated fax only) 3 Fax Detection Medthod (CNG or CED) 4 Detect Phone CED Phase Reversal (Checked) 5 Detect Network CED Phase reversal (Checked) With the above settings on my GV dedicated Fax line on port 2 of Obi202 I have managed to fax at 33.6kbps far more reliably. Updating this post to show the additional Fax settings that I've  found for my dedicated Fax line (See Attached) CallWaitingEnable (unchecked) UseForFaxOnly (Checked) DetectFaxPageBreak (Checked) UseForModemOnly (Unchecked) FaxDetectionMethod (CNG or CED) DetectPhoneCED...

APC UPS Discharge problem reset / fix

APC UPS Discharge problem reset/fix (instructions) http://www.joeteck.com/apc.htm "Remove the net card" Serial Setting  2400 Baud 8 bits 1 stop no parity Xon/Xof This is for the following people who have these symptoms •  You ran Power chute software and noticed your run time is less than it should be. •  You replaced your batteries with a new one(s) and your run time is still very low. •  Your Battery LED lights are flashing/blinking without a full load. •  Your UPS program tells you, "UPS battery is discharged" from power chute software. Follow these steps to repair this un-documented solution. ***You need the smart-UPS serial cable to do this process. It is black, not gray. ***     •  Close power chute software, and stop the "APC - UPS power chute" service. •  Open HyperTerminal. Start > Programs > Accessories > Hyperterminal > Hyperterminal •  Enter in a name, such as APC repair. •  Be sure the settings are as follow...

Adtran CLI

 show ip interface Debug Output COMMAND DESCRIPTION show debugging shows current enabled debug commands debug sip stack messages shows sip debug information debug isdn l2-formatted shows isdn debug information (easier use) debug voice verbose shows all voice messaging debug isdn verbose shows all isdn messaging debug interface T1 0/4 rbs shows robbed bit signaling from CAS circuit undebug all turns off all debugging Utility Commands COMMAND DESCRIPTION clear count media counters on media-gateway reset clear counters clears counters on interfaces no events turns off messages to the current session ping ping an IP address traceroute trace the router path to a destination IP address wall sends a broadcast message to all current users sip trunk-registration force-register forces sip re-registration Show Commands COMMAND DESCRIPTION show sip trunk-registration shows registration status show media-gateway summary shows media gateway channel status show media-gateway channel 0/2.1 shows m...