APC FIX

Image
found this post  https://web.archive.org/web/20211203171108/http://apc-fix.com/articles/187 For APCFiX users How to use APCFiX to fix the problem with "Discharge Battery" messages after you replace batteries by yourself UPS and the computer must be connected using APC smart-signaling COM port cable ( for example: 940-0024С , 940-1524D ), similar as using with Power Chute. ( USB connection not supported ) For correct APCFiX functionality you should remove any SNMP adapter from UPS  ( if any SNMP adapter inserted ) APCFiX supports AP9620 using with new SMX & SMT APC ups, but with a lot of limitations. Unload from PC memory PoweChute resident part.  So, COM port can be used by APCFiX. Run APCFiX. In the Options menu, set the check in front of "Smart-UPS 3Gen. Battery Const.AUTO Fix". In the Choose Port select COM port. Wait until the on-screen information from UPS. DOWNLOAD APCFiX If you do not have any original APC cables, you can made one by yourself

How to Performing Logic Reset on APC Smart-UPS and a cold start and brain dead on Smart-UPS

 https://www.apc.com/us/en/faqs/FA156611/ https://youtu.be/Q4-0lAVBATM https://youtu.be/jeVqtc2dbbc Cause: The Cold start procedure is used to determine if a UPS is functional if it will not turn on when plugged into utility power. The Brain Dead procedure performs a hard reset of the Smart-Ups microprocessor. It does not however reset saved preferences. Resolution: Cold Start: This is a great way to establish if a UPS will not turn on due to bad input power. Never use a Cold Start to troubleshoot a bad battery LED as it will clear the light most every time even if the battery is actually bad. This is because the self-test is comparing the battery health compared to the load attached. If there is no load attached, the battery will appear healthy.   1) Turn off and unplug the Smart-UPS from wall. Remove any attached load. 2) Press and hold the power button (labeled ""I/TEST"" on legacy non-LCD screen units) on the front of the UPS until you hear a LONG beep. 3) Let g...

APC UPS Discharge problem reset / fix

APC UPS Discharge problem reset/fix (instructions) http://www.joeteck.com/apc.htm "Remove the net card" Serial Setting  2400 Baud 8 bits 1 stop no parity Xon/Xof This is for the following people who have these symptoms •  You ran Power chute software and noticed your run time is less than it should be. •  You replaced your batteries with a new one(s) and your run time is still very low. •  Your Battery LED lights are flashing/blinking without a full load. •  Your UPS program tells you, "UPS battery is discharged" from power chute software. Follow these steps to repair this un-documented solution. ***You need the smart-UPS serial cable to do this process. It is black, not gray. ***     •  Close power chute software, and stop the "APC - UPS power chute" service. •  Open HyperTerminal. Start > Programs > Accessories > Hyperterminal > Hyperterminal •  Enter in a name, such as APC repair. •  Be sure the settings are as follow...